Standards Laboratory
Contact
In support of California’s ambient air monitoring program, the California Air Resources Board (CARB) operates and maintains a Standards Laboratory to provide authoritative standards for determining whether data meets established data quality objectives. The Standards Laboratory provides metrological certification/verification services for the gases and equipment used to perform required quality assurance activities (i.e., calibrations, checks, and audits). The gases evaluated are contained in compressed gas cylinders and are typically single pollutant or multi-blends (CO, SO2, and NO). The equipment evaluated includes ozone transfer standards, flow measuring devices (i.e., orifices, mass flow meters, and mass flow controllers) and meteorological sensors (i.e., wind speed, temperature, pressure, and relative humidity). The Standards Laboratory has developed a Quality Assurance Manual that details the policies and procedures that ensure consistent collection and validation of the data generated by the Standards Laboratory. Standard Operating Procedures (SOP) for conducting certifications/verifications are currently under review and are being revised. If you would like to view a copy of the Quality Assurance Manual, or a Standards Laboratory SOP, please reach out to the Certification Services Contact at the bottom of the page.
If you would like to subscribe to the Standards Laboratory Section Newsletter and receive updates and important announcements regarding certification stations and primary reference standard status, please click here to join the email list for the Standards Lab.
SOP Number | Standard Operating Procedure Title | Effective Date |
---|---|---|
5720-2 | Standard Operating Procedure for the Verification and Certification of Ozone Primary and Transfer Standards Using the Standard Reference Photometer | 09/05/13 |
5722-1 | Standard Operating Procedure for the Certification of Calibration and Audit Gas Standards | 12/31/99 |
002-0 | Standard Operating Procedure for Verification of High Flow Transfer Standards | 7/11/14 |
004-2 | Standard Operating Procedure for the Verification and Calibration of Primary and Transfer Low Flow Standards | 5/29/15 |
005-0 | Standard Operating Procedure for the Verification and Calibration of Relative Humidity Devices | 3/11/14 |
006-0 | Standard Operating Procedure for Verification and Calibration of Temperature Devices | 7/11/14 |
007-0 | Standard Operating Procedure for the Verification and Calibration of Pressure Devices | 4/21/15 |
008-0 | Standard Operating Procedure for the Verification of Anemometer Drives | 5/28/15 |