COLUSA COUNTY AIR POLLUTION CONTROL DISTRICT
REGULATION II - PROHIBITIONS
RULE 2.28 - HEXAVALENT CHROMIUM AIRBORNE TOXIC CONTROL MEASURE - DECORATIVE AND HARD CHROME PLATING AND CHROMIC
ACID ANODIZING FACILITIES
(Adopted 09/26/89)
a. DECORATIVE CHROME PLATING REQUIREMENTS
b. HARD CHROME PLATING AND CHROMIC ACID ANODIZING FACILITIES REQUIREMENTS
A. The chromium emissions from the emissions collection system serving the plating tank have been reduced by 95 percent or more of the uncontrolled chromium emissions or,
B. The chromium emissions from the emissions collection system serving the plating tank have been reduced to less than 0.15 milligrams (mg) of chromium per ampere-hour of electrical charge applied to the plating tank.
A. The chromium emissions from the emissions collection systems serving the plating tanks have been reduced by at least 99 percent of the uncontrolled chromium emissions from the hard chrome plating or chromic acid anodizing facility or,
B. The chromium emissions from the emissions collection systems are reduced to less than 0.03 mg of chromium per ampere-hour of electrical charge applied to the tanks.
A. The chromium emissions from the emissions collection systems serving the plating tanks have been reduced by at least 99.8 percent of the uncontrolled chromium emissions from the hard chrome plating or chromic acid anodizing facility or,
B. The chromium emissions for the emissions collection systems are reduced to less than 0.006 mg of chromium
per ampere-hour electrical charge applied to the tanks.
c. COMPLIANCE SCHEDULE